Jobsite safety for the General Building (B) Examination: fall protection, ladders and scaffolds, excavations, electrical hazards, temporary traffic control, haul vehicles and health hazards. These are original practice notes, not materials of the CSLB or PSI, based on California texts in force on January 1, 2027 (Title 8, CA MUTCD and several California codes). Figures are those read in November 2026 and can change.

Fall protection and openings

Ladders, scaffolds and housekeeping

Excavations

Electrical hazards

Traffic control and haul vehicles

Health hazards

Take the free test · full question bank and mock exams with a subscription

Sample questions (5)

1. Under Title 8, section 1670, employees exposed to a fall of MORE than what distance from the perimeter of a structure must wear approved fall protection?

  1. A drop of more than 4 feet
  2. A drop of more than 7 1/2 feet
  3. A drop of more than 10 feet
  4. A drop of more than 15 feet

Title 8, section 1670 requires fall arrest, restraint or positioning systems for employees exposed to “falling in excess of 7 1/2 feet from the perimeter of a structure”. Four feet is not the trigger in that section, and ten and fifteen feet are higher than the distance the section sets.

2. What is the MINIMUM breaking strength required for lanyards and vertical lifelines used in a personal fall arrest system?

  1. 1,800 pounds
  2. 3,000 pounds
  3. 5,000 pounds
  4. 10,000 pounds

Title 8, section 1670 states that “Lanyards and vertical lifelines shall have a minimum breaking strength of 5,000 pounds.” The 1,800 pound figure is the maximum arresting force on a worker in a harness, 3,000 pounds is the tensile load for self-retracting devices that limit free fall to 2 feet or less, and 10,000 pounds applies to a lifeline shared by two employees in an elevator hoistway.

3. A personal fall arrest system must be rigged so that an employee can free fall a MAXIMUM of how far?

  1. A free fall of 2 feet
  2. A free fall of 3.5 feet
  3. A free fall of 6 feet
  4. A free fall of 7 1/2 feet

Title 8, section 1670 requires the system to be rigged so that an employee “can neither free fall more than 6 feet, nor contact any lower level”. Two feet is the free fall limit for a positioning device, 3.5 feet is the maximum deceleration distance, and 7 1/2 feet is the exposure height at which fall protection is first required.

4. What is the MINIMUM number of times each year that a competent person must inspect each personal fall arrest system, in addition to the check before each use?

  1. One time a year
  2. Two times a year
  3. Four times a year
  4. Twelve times a year

Title 8, section 1670 requires each system to be inspected “not less than twice annually by a competent person” and the date of each inspection to be documented. One inspection a year falls short of that minimum, while four and twelve exceed the minimum the section sets.

5. Which action is NOT allowed with a personal fall arrest system?

  1. Attaching the lanyard to a temporary guardrail
  2. Inspecting the harness and lanyard before use
  3. Shielding a lifeline from cuts and abrasion
  4. Giving each worker a separate vertical lifeline

Title 8, section 1670 says personal fall arrest systems shall not be attached to hoists, “nor shall they be attached to guardrails”. Inspection before each use, protection of lifelines against being cut or abraded, and a separate vertical lifeline for each employee are all required by the same section.