What this topic covers
Jobsite safety for the General Building (B) Examination: fall protection, ladders and scaffolds, excavations, electrical hazards, temporary traffic control, haul vehicles and health hazards. These are original practice notes, not materials of the CSLB or PSI, based on California texts in force on January 1, 2027 (Title 8, CA MUTCD and several California codes). Figures are those read in November 2026 and can change.
Fall protection and openings
- Trigger height: fall protection for exposure to a fall of more than 7 1/2 feet from a structure's perimeter (Title 8, section 1670).
- Free fall: no more than 6 feet, and no contact with a lower level (Title 8, section 1670).
- Anchorage: personal fall arrest systems are not attached to guardrails or hoists (Title 8, section 1670).
- Wall framing: protection on surfaces 6 feet or more above the level below (Title 8, section 1716.2).
- Opening covers: marked Opening--Do Not Remove in letters at least one inch high (Title 8, section 1632).
Ladders, scaffolds and housekeeping
- Ladder rails: extend at least 36 inches above the upper landing (Title 8, sections 1675 and 3276).
- Defective ladders: withdrawn from service and tagged Dangerous, Do Not Use (Title 8, section 3276).
- Scaffold planks: overlap the ledgers at least 6 inches at each end (Title 8, section 1644).
- Dropping waste: only into an area guarded by fences or barricades, with warning signs (Title 8, section 1513).
Excavations
- Protective system: required unless the excavation is in stable rock, or under 5 feet deep with no sign of cave-in found by a competent person (Title 8, section 1541.1).
- Inspections: daily by a competent person, and again after every rainstorm or other hazard-increasing event (Title 8, section 1541).
- Atmosphere testing: before entry into excavations over 4 feet deep where a hazardous atmosphere could exist (Title 8, section 1541).
- Permit: from the Division (Cal/OSHA), not the Registrar, for trenches 5 feet or deeper that a person must enter (Labor Code section 6500).
Electrical hazards
- Damaged cords: not used until repaired; tape is not a repair (Title 8, section 2405.4).
- GFCI: opens the circuit when current leaks to ground; with an assured equipment grounding conductor program, one of the two protection methods (Title 8, section 2405.4).
Traffic control and haul vehicles
- Temporary traffic control zone: four areas (CA MUTCD Section 6B.03), among them the transition area (6B.05), the activity area where work takes place (6B.06) and the termination area (6B.07); the plan is prepared before the site is occupied (CA MUTCD Section 6A.02).
- Flagger: the STOP/SLOW paddle is the preferred device; flags are for emergencies (CA MUTCD Sections 6D.02 and 6D.03); garments visible at 1,000 feet (Title 8, section 1599).
- Backing: automatic warning device on haul vehicles of 2 1/2 cubic yards or more, plus a signaler where noise or congestion obscures the alarm (Title 8, section 1592).
- Loads and dust: aggregate such as sand is covered on a highway (Vehicle Code section 23114); dust kept from reducing visibility (Title 8, section 1590).
Health hazards
- Asbestos: wet methods, no dry sweeping (Title 8, section 1529); the owner posts the warning notice (Health and Safety Code section 25916).
- Hazardous substance removal: the qualifier must pass the hazardous substance certification examination (Business and Professions Code section 7058.7).
- Heat illness: one quart of water per employee per hour; an employee with symptoms is not sent back until they abate, and not before 5 minutes in the shade (Title 8, section 3395).
- Silica dust: engineering controls first, such as wet cutting at a masonry saw (Title 8, section 5144).
Sample questions (5)
1. Under Title 8, section 1670, employees exposed to a fall of MORE than what distance from the perimeter of a structure must wear approved fall protection?
- A drop of more than 4 feet
- A drop of more than 7 1/2 feet
- A drop of more than 10 feet
- A drop of more than 15 feet
Title 8, section 1670 requires fall arrest, restraint or positioning systems for employees exposed to “falling in excess of 7 1/2 feet from the perimeter of a structure”. Four feet is not the trigger in that section, and ten and fifteen feet are higher than the distance the section sets.
2. What is the MINIMUM breaking strength required for lanyards and vertical lifelines used in a personal fall arrest system?
- 1,800 pounds
- 3,000 pounds
- 5,000 pounds
- 10,000 pounds
Title 8, section 1670 states that “Lanyards and vertical lifelines shall have a minimum breaking strength of 5,000 pounds.” The 1,800 pound figure is the maximum arresting force on a worker in a harness, 3,000 pounds is the tensile load for self-retracting devices that limit free fall to 2 feet or less, and 10,000 pounds applies to a lifeline shared by two employees in an elevator hoistway.
3. A personal fall arrest system must be rigged so that an employee can free fall a MAXIMUM of how far?
- A free fall of 2 feet
- A free fall of 3.5 feet
- A free fall of 6 feet
- A free fall of 7 1/2 feet
Title 8, section 1670 requires the system to be rigged so that an employee “can neither free fall more than 6 feet, nor contact any lower level”. Two feet is the free fall limit for a positioning device, 3.5 feet is the maximum deceleration distance, and 7 1/2 feet is the exposure height at which fall protection is first required.
4. What is the MINIMUM number of times each year that a competent person must inspect each personal fall arrest system, in addition to the check before each use?
- One time a year
- Two times a year
- Four times a year
- Twelve times a year
Title 8, section 1670 requires each system to be inspected “not less than twice annually by a competent person” and the date of each inspection to be documented. One inspection a year falls short of that minimum, while four and twelve exceed the minimum the section sets.
5. Which action is NOT allowed with a personal fall arrest system?
- Attaching the lanyard to a temporary guardrail
- Inspecting the harness and lanyard before use
- Shielding a lifeline from cuts and abrasion
- Giving each worker a separate vertical lifeline
Title 8, section 1670 says personal fall arrest systems shall not be attached to hoists, “nor shall they be attached to guardrails”. Inspection before each use, protection of lifelines against being cut or abraded, and a separate vertical lifeline for each employee are all required by the same section.