What this topic covers
Finish Trades on the General Building (B) Examination: painting, drywall and ceilings, lead-safe work, tile and flooring, cabinets and millwork, doors and windows, landscaping and irrigation. These are original practice notes, not materials of the CSLB or PSI. Lead rules are based on the Health and Safety Code in force on January 1, 2027; code sections refer to the 2025 California Building Standards Code (Title 24), to check in the edition in force; the rest uses standard methods of the trade.
Painting, drywall and ceilings
- Primer-sealer: face paper and joint compound absorb paint differently, so unprimed drywall dries with patchy sheen and color.
- Wallcovering primer: seals the surface so paste does not soak in and later removal is easier.
- Paint quantity: wall area less openings, times coats, divided by coverage, rounded up: 396 square feet x 2 / 350 = 2.26, so 3 gallons.
- Screws: head set just below the surface in a dimple, face paper unbroken.
- Garage separation: the board works only as a continuous membrane; an unprotected hole for a recessed light defeats it (California Residential Code Section R302.6; check the current code).
- Suspended ceilings: splay wires resist lateral load, a compression strut stops uplift, hanger wires carry weight.
Lead-safe work
- Abatement: work to reduce or eliminate lead hazards on a permanent basis, to last 20 years or more (Health and Safety Code section 105254; figure read in 2026, subject to change).
- Training: a completion form only after a DHS-approved course, offered only by an accredited training provider (section 105252).
- Lead hazard: work may not create one (section 105255); dry power sanding without dust control does, while misting, plastic containment and HEPA cleaning control dust.
Tile and flooring
- Grout: fills joints and supports edges, but the setting mortar bonds the tile. Back-buttering: mortar on the tile back for full contact.
- Shower pan: rise = distance from drain to farthest wall x slope; 3 ft x 0.25 inch per foot = 0.75 inch.
- Shower walls: nonabsorbent surface (California Residential Code Section R307; check the current code).
- Floating floor: never nailed; expansion gap, staggered end joints, approved underlayment. A reducer strip bridges a small height change.
- Boxes and trim: area x (1 + waste) / box coverage, rounded up; baseboard = perimeter less door openings.
Cabinets, doors and windows
- Wall cabinets: screws through the hanging rail into studs or blocking; filler strips scribed to the wall give doors room.
- Scarf joint: long bevel splice for molding that hides seasonal movement.
- Prehung door: plumb and fasten the hinge-side jamb first.
- Sill pan: drains to the exterior, with a back dam on the interior side.
- Safety glazing: required in hazardous locations; tempered panes carry a permanent mark (California Residential Code Section R308; check the current code).
- Escape openings: bars must release from inside without a key, tool or special knowledge (California Residential Code Section R310; check the current code).
- Energy label: U-factor and SHGC on the unit (California Energy Code Section 110.6; check the current code); a lower U-factor insulates better.
Landscaping and site work
- Hydrozoning: plants with similar water needs on one valve; weather-based controllers adjust to local weather data.
- MWELO: the Model Water Efficient Landscape Ordinance limits irrigation water through design, plants and efficient irrigation.
- Retaining walls: gravel backfill, perforated pipe and weep holes drain water; a surcharge calls for a permit (California Residential Code Section R105.2; check the current code).
- Fences: a licensed land surveyor marks the legal boundary.
Sample questions (5)
1. A room has walls 12 feet by 15 feet and an 8-foot ceiling. Door and window openings total 36 square feet and are not painted. One gallon covers 350 square feet. How many whole gallons are needed to paint the walls only with two coats?
- 1 gallon
- 2 gallons
- 3 gallons
- 4 gallons
The wall area is 2 x (12 + 15) x 8 = 432 square feet, less 36 for openings, which is 396 square feet. Two coats need 792 square feet, and 792 / 350 = 2.26, so 3 gallons must be bought. One gallon comes from 396 / 350 = 1.13 rounded down, and 2 gallons from rounding 2.26 down, which leaves the job short. Four gallons comes from adding the 180-square-foot ceiling, which is not painted here.
2. A ceiling measures 12 feet by 16 feet. How many 4 x 8 foot sheets of gypsum board should be ordered with a 10 percent waste allowance?
- 6 sheets
- 7 sheets
- 14 sheets
- 27 sheets
The ceiling is 12 x 16 = 192 square feet; adding 10 percent gives 211.2 square feet, and a 4 x 8 sheet covers 32 square feet, so 211.2 / 32 = 6.6, which rounds up to 7 sheets. Six sheets ignores the waste allowance, 14 sheets divides by 16 square feet as if the sheet were 4 x 4, and 27 sheets divides by the 8-foot sheet length instead of the 32-square-foot sheet area.
3. A 12-foot by 16-foot ceiling is covered with 4 x 8 foot sheets in three rows of two sheets, laid along the 16-foot length. How many feet of tape are needed if only the joints between sheets are taped, not the perimeter?
- 32 feet
- 44 feet
- 56 feet
- 100 feet
The two long joints between the three rows are 2 x 16 = 32 feet, and the three end joints are 3 x 4 = 12 feet, so the total is 44 feet. Thirty-two feet forgets the end joints, 56 feet is the perimeter of the room, which is not taped here, and 100 feet adds the perimeter to the joint total.
4. A suspended ceiling covers a room 14 feet by 18 feet. How many 2 x 4 foot lay-in panels are needed, rounded up, with no waste allowance?
- 16 panels
- 31 panels
- 32 panels
- 63 panels
The room is 14 x 18 = 252 square feet and a panel covers 8 square feet, so 252 / 8 = 31.5, which rounds up to 32 panels. Sixteen panels divides by 16 square feet, 31 rounds the fraction down and leaves a gap, and 63 divides by 4 square feet as if the panels were 2 x 2.
5. A wall of 200 square feet receives plaster with a total thickness of 3/4 inch for all three coats. How many cubic yards of plaster are needed before any waste allowance?
- 0.46 cubic yards
- 4.17 cubic yards
- 5.56 cubic yards
- 12.50 cubic yards
The thickness is 0.75 / 12 = 0.0625 foot, so the volume is 200 x 0.0625 = 12.5 cubic feet, and 12.5 / 27 = 0.46 cubic yards. Dividing the 12.5 cubic feet by 3 instead of 27 gives 4.17, skipping the inch-to-foot conversion gives 200 x 0.75 / 27 = 5.56, and 12.50 leaves the answer in cubic feet.